The longitudinal joint is a 25mm high double lock standing seam.
Standing seam zinc roof details.
Standing seam panels for wall cladding.
The use of profiling and seaming machines for the closure of longitudinal seam joints significantly reduces installation time.
Zinc at 0 7mm thick is the standard roofing thickness.
Standing seam warm roof on insulated metal faced panels.
However for long panels or exposed sites 0 8mm thick zinc should be considered.
Standing seam warm roof on cellular glass insulation.
Standing seam warm roof on plywood bonded to phenolic foam.
Supporting the zinc roof standing seam trays are not self supporting and require a fully or almost fully supporting substrate against which they rest and to which their clips are fixed.
Standing seam roof panels can be up to 600mm wide with 530mm and 430mm wide panels also being standard non standard widths less than 600mm but greater than 150mm are also possible.
Standing seam g3.
Standing seam cold roof on open gap timber boarding.
The double lock welt of the seam is.
The standing seam should always follow the line of maximum pitch if possible.
The seams themselves are.
The low height of the seams 25 or 32 mm contributes to the modernity lightness and regularity of the roof and facade while highlighting its architectural purpose.
Rheinzink double lock standing seam roofing the double lock standing seam is a further development of the original hollow seam or the simple standing seam.
Standing seam zinc roofing design appearance.